EnvironmentalMartindale's Environmental Series meters have been introduced to compliment the all ready extensive range of electrical test equipment. The new products are instruments suitable for most environmental applications.
| ||||||||||||||||||||||||||||||||
This rapid responding carbon meter is ideal for checking safety. A beeper gives audible indication, speeding up with CO concentration, and becoming a continuous tone above 200 ppm. Max and hold buttons allow one reading or the highest over a period of time to be displayed. Technical specifications C090 Instruction manual |
|||||||||||||||||||||||||||||||||
This compact sound level meter can be used one handed or it can be mounted on a tripod for measuring over large periods. The Time Weighting can be set to slow (for normal use) or fast to check the average level of frequency noise. Similarly the Frequency Weighting can be A or C with C suitable for low frequency noise. An AC/DC output allows capture of reading for later analysis (output is approx 10mV DC/dB). Technical specifications SP75 Instruction manual | |||||||||||||||||||||||||||||||||
The handbook gives details of conversion factors for different light wavelengths allowing more accurate measurements. Peak hold & hold allow a maximum reading to be recorded or one particular result to be kept. Results can be shown in lux or foot candles. LM90: 20 lux to 20k lux (preferred for emergency lighting applications LM92: 200 lux to 200k lux (more sensitive in higher ranges) Technical specification LM90/92 Instruction manual |
|||||||||||||||||||||||||||||||||
A K Type thermocouple can also be used with a variety of probes to take contact temperature readings. In addition the emissivity is variable, to allow for a wide range of source types. Technical specification IR90 Instruction manual | |||||||||||||||||||||||||||||||||
This pistol style infra red thermometer has a laser marker to ensure accurate spot measurement. The display can show temperatures in Fahrenheit or Celsius. A limit function allows you to set upper and lower temperature thresholds and a tone alerts if the limits are exceeded. An optional auto power off feature can conserve battery life. Technical specifications IR88 Instruction manual |
|||||||||||||||||||||||||||||||||
This meter displays temperature (C or F) and airflow at the same time. Maximum and minimum figures for flow and temperature can be shown. For more accurate measurements, up to 8 readings can be taken and automatically averaged. In addition, measurements can be taken over either 2 or 16 seconds with the average of 2 or 16 readings being displayed. Airflow measurement can be displayed as: metres/second, feet/minute, knots, mph, kph. Technical specification AV90 Instruction manual |
|||||||||||||||||||||||||||||||||
|
|
An easy to use, low cost pass / fail microwave leakage detector suitable for commercial and domestic microwave ovens. It is designed to comply with national standards on permitted exposure levels. The TEK500 includes a self test which simulates a real microwave input to ensure the unit is working correctly at all times. This meter can test microwave ovens for potentially dangerous leaks with the accessories supplied. Using the measuring beaker and thermometer supplied microwave power output may be assessed. Microwave test labels (MARMICRO) come in rolls of 500 and cost &35.00 each. Technical specification TEK500 Instruction manual |
||||||||||||||||||||||||||||||||
|
The Martindale current calibrator has sink, source and monitor modes for 0 to 20mA. It is ideal for most process control as well as general purpose signal injection applications. This handheld, fully portable unit has a 3½ digit display with overload protection for additional safety. Technical specification Instruction manual |
||||||||||||||||||||||||||||||||
|
back to the top |
Reliably locates live or dead cables through a variety of building aggregates and sub-surfaces. This unit uses both visual indication and an audible tone to pin point cables at a depth of up to 25mm* with a high degree of accuracy. It can even locate cables in close proximity to ferrous and non ferrous metal frameworks - an application not previously available with conventional units. Headphones are supplied for use where background noise is excessive. * Depth of detection may vary dependant on cable type. Technical specification Instruction manual |
||||||||||||||||||||||||||||||||
| |
|||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||